top of page
Parameter
Condition
Min
Max
Unit
Supply voltage (VccA, VccB)
1.65
5.5
V
Input voltage (VI)
0
5.5
V
Input/output voltage (VIO)
Active state
0
Vcco
V
High-level output current (IOH)
Vcco = 4.5 V to 5.5 V
-32
mA
Low-level output current (IOL)
Vcco = 4.5 V to 5.5 V
32
mA
Input transition rise or fall rate (Δt/Δv)
Vcco = 4.5 V to 5.5 V
5
ns/V
Input clamp current (IIK)
VI < 0
-50
mA
Output clamp current (IOK)
VO < 0
-50
mA
Continuous output current (IO)
±50
mA
Continuous current through each VCCA, VCCB, and GND (IO)
±100
mA
Input leakage current (Ioff)
VccA = 0 V, VccB = 0 to 5.5 V VccA = 0 to 5.5 V, VccB = 0 V
±1
±2
µA
Output leakage current (Ioz)
VccA, VccB = 1.65 V to 5.5 V
±1
±2
µA
Supply current A (IccA)
20
µA
Supply current B (IccB)
20
µA
Total supply current (IccA + IccB)
VccA, VccB = 1.65 V to 5.5 V
30
µA
Input capacitance (Ci)
VccA, VccB = 3.3 V
5
pF
Page 1 of 1

ZG54LVC245

Bus transceiver, automotive-grade, SEL immune to LET of 60 MeV-cm2/mg.

The ZG54LVC245 is a 16-bit bus transceiver with configurable level shifting / voltage translation. The part features a maximum Icc of 1 uA and typical propagation delay of 1 to 8 ns at 3.3 V. The part is qualified to AEC-Q100 standards. View the reliability testing flow here. We have performed radiation qualification for SEL immunity up to LET of 60 MeV-cm2/mg. The part is available in a TSOP-48 package.

bottom of page